Description
Complete calibration system with components well matched to each other. A special torque transmission system avoids movement of the torque application point during calibration.
Application
Calibration means the regular checking of the precision and reliability of torque drive tools and the documenting and management thereof. For torque drive tools to deliver precise and reliable measurement values over a long period of time, they must be checked regularly for calibration and documented.
Supplied with
Mechanical operating device for even and precise loading of the torque wrench. This ensures that in accordance with DIN EN ISO 6789 the torque is applied slowly and progressively.
- 2 transducers Laboratory size 6 – 60 Nm and 40 – 400 Nm (display divergence from the measured value is ±0.5 %) with DAkkS calibration certificate.
- Software for generating calibration certificates to DIN EN ISO 6789 and measuring equipment management.
- USB adaptor cable for connecting measurement transducers to a PC.
- 4 square drive adaptors to accept various square drives.
Technical Data
Test certificate Manufacturer’s test certificate
Torque measuring accuracy ±0.5 %
Interface USB interface
The direction of tightening For right and left-hand tightening
Calibration O4